Skip to content

Application review

2741 38th Street, Sacramento, CA 95817

In review

APN 013-0271-009 · app_fcf72085-2753-4442-892d-482e699d4c2e · submitted Jun 7, 2026 · accepted complete Jun 7, 2026

Completeness determination14 of 15 days left
Decision55 of 60 days left

City cycle targets for residential new buildings: 20/15/5 working days for cycles 1/2/3 (CDD-0294, rev 03-04-2026) — an expectation, not a promise.

Parcel

APN
013-0271-009
Zone
R-1
Lot area
5,200 sq ft
Overlays
none
GIS source
demo-snapshot · fetched Jun 10, 2026

Application

Standards path
B — State standards (≤800 sf, 18 ft, 4-ft setbacks)
Permit holder
Property owner
Valuation
$128,000
New sq ft (living)
748 (748 first / 0 second)
Garage sq ft
0
Stories
1
Description of work
Construct a new detached 748 sf one-story accessory dwelling unit (1 bed / 1 bath) in the rear yard; all-electric, rooftop PV; no demolition, no fencing.

Documents

  • delgado-cdd0104-address-request.pdfcdd0104 · v1 · uploaded Jun 6, 2026Download
    • Readings · source · confidence
    • address_request.completeyes
      from cdd01040.97
  • delgado-CYC1-APP-cdd0200.pdfcdd0200_rendered · v1 · uploaded Jun 6, 2026Download
    • Readings · source · confidence
    • package.app_size_mb9.60
      from cdd0200_rendered0.97
    • package.export_naming_compliantyes
      from cdd0200_rendered0.97
    • package.bookmarks_compliantyes
      from cdd0200_rendered0.97
    • document.pdf_restrictions_compliantyes
      from cdd0200_rendered0.97
  • delgado-cdd0220-owner-builder-wet-signed.pdfcdd0220 · v1 · uploaded Jun 7, 2026Download
    • Readings · source · confidence
    • signature.wet_signedyes
      from cdd02200.97
    • acknowledgments.initialed_count12
      from cdd02200.97
  • delgado-final-certification-wet-signed.pdffinal_certification_signed · v1 · uploaded Jun 7, 2026Download
    • Readings · source · confidence
    • signature.wet_signedyes
      from final_certification_signed0.97
    • signature.date2026-06-02
      from final_certification_signed0.97
  • delgado-owner-builder-declaration-wet-signed.pdfowner_builder_declaration_signed · v1 · uploaded Jun 7, 2026Download
    • Readings · source · confidence
    • signature.wet_signedyes
      from owner_builder_declaration_signed0.97
    • signature.date2026-06-02
      from owner_builder_declaration_signed0.97
  • delgado-adu-plan-set-v2.pdfplan_set · v1 · uploaded Jun 6, 2026Download
    • Readings · source · confidence
    • cover_sheet.address
      2741 38th Street, Sacramento, CA 95817from plan_set0.97
    • cover_sheet.sheet_indexyes
      from plan_set0.97
    • cover_sheet.work_description
      Construct a new detached 748 sf one-story accessory dwelling unit (1 bed / 1 bath) in the rear yard; all-electric, rooftop PV; no demolition, no fencing.from plan_set0.97
    • cover_sheet.description_of_work
      Construct a new detached 748 sf one-story accessory dwelling unit (1 bed / 1 bath) in the rear yard; all-electric, rooftop PV; no demolition, no fencing.from plan_set0.97
    • cover_sheet.occupancyR-3
      from plan_set0.97
    • cover_sheet.construction_typeV-B
      from plan_set0.97
    • cover_sheet.sprinklersno
      from plan_set0.97
    • cover_sheet.sprinklers_primaryno
      from plan_set0.97
    • cover_sheet.toilet_counts
      primary dwelling: 2 WC; ADU: 1 WCfrom plan_set0.97
    • cover_sheet.building_typeall_electric
      from plan_set0.97
    • cover_sheet.designer_declarationyes
      from plan_set0.97
    • cover_sheet.codes_declaration
      2025 Title 24 with City of Sacramento amendments (ORD 2025-0031; City Code §15.04.050)from plan_set0.97
    • cover_sheet.code_cycle_declaration
      2025 Title 24 with City of Sacramento amendments (ORD 2025-0031; City Code §15.04.050)from plan_set0.97
    • site_plan.utility_connection_pointsyes
      from plan_set0.97
    • site_plan.abandoned_septic_notenone on parcel
      from plan_set0.97
    • site_plan.setbacks_dimensionedyes
      from plan_set0.97
    • site_plan.north_arrowyes
      from plan_set0.97
    • site_plan.easements_driveways_drainageyes
      from plan_set0.97
    • site_plan.sewer_line_details
      4-in ABS, 2% slope, tie-in at existing lateralfrom plan_set0.97
    • site_plan.side_setback_ft3.50
      from plan_set0.97
    • site_plan.rear_setback_ft4.50
      from plan_set0.97
    • site_plan.front_setback_ft27
      from plan_set0.97
    • site_plan.dist_to_front_line68
      from plan_set0.97
    • site_plan.separation_primary_ft8
      from plan_set0.97
    • site_plan.adu_sqft748
      from plan_set0.97
    • site_plan.adu_footprint_sqft748
      from plan_set0.97
    • site_plan.fire_separation_ft10
      from plan_set0.97
    • site_plan.utility_equipment_screenedyes
      from plan_set0.97
    • floor_plan.room_usesyes
      from plan_set0.97
    • floor_plan.dimensionsyes
      from plan_set0.97
    • floor_plan.window_door_sizes_typesyes
      from plan_set0.97
    • floor_plan.ceiling_heightyes
      from plan_set0.97
    • floor_plan.ceiling_height_ft8
      from plan_set0.97
    • floor_plan.entrance_faces_roadway_or_open_spaceyes
      from plan_set0.97
    • elevations.views_nsewyes
      from plan_set0.97
    • elevations.height_ft15
      from plan_set0.97
    • elevations.blank_wall_area_sqft140
      from plan_set0.97
    • elevations.mechanical_equipment_concealedyes
      from plan_set0.97
    • sections.longitudinalyes
      from plan_set0.97
    • sections.transverseyes
      from plan_set0.97
    • structural_plans.foundation_footing_detailsyes
      from plan_set0.97
    • structural_plans.roof_ceiling_framingyes
      from plan_set0.97
    • structural_plans.floor_framingyes
      from plan_set0.97
    • structural_plans.braced_shear_wall_plansyes
      from plan_set0.97
    • structural_plans.connection_detailsyes
      from plan_set0.97
    • electrical_plan.panel_locations_amperage_busbaryes
      from plan_set0.97
    • electrical_plan.switch_receptacle_lighting_scaledyes
      from plan_set0.97
    • electrical_plan.meter_count1
      from plan_set0.97
    • title24_report.certificates_of_complianceyes
      from plan_set0.97
    • title24_report.code_cycle2025
      from plan_set0.97
    • title24_report.climate_zone12
      from plan_set0.97
    • calgreen_checklist.cdd0183yes
      from plan_set0.97
    • pv_plans.module_layoutyes
      from plan_set0.97
    • pv_plans.one_line_diagramyes
      from plan_set0.97
    • pv_plans.spec_sheetsyes
      from plan_set0.97
    • pv_plans.cec_labelsyes
      from plan_set0.97
    • pv_plans.attachment_detailsyes
      from plan_set0.97
    • pv_plans.smud_confirmation_letteryes
      from plan_set0.97
    • plan_set.vector_contentyes
      from plan_set0.97
    • plan_set.sheet_size_scale_compliantyes
      from plan_set0.97
    • package.plans_size_mb42.70
      from plan_set0.97
    • site_plan.lot_coverage_pct31.20
      from plan_set0.97
    • site_plan.has_balconyno
      from plan_set0.97
    • site_plan.fencing_in_scopeno
      from plan_set0.97
    • site_plan.adu_in_front_setbackno
      from plan_set0.97
  • delgado-cdd0312-checklist.pdfsubmittal_checklist_copy · v1 · uploaded Jun 6, 2026Download
    • Readings · source · confidence
    • checklist.formCDD-0312 rev 01-21-2025
      from submittal_checklist_copy0.97
  • delgado-workers-comp-wet-signed.pdfworkers_comp_signed · v1 · uploaded Jun 7, 2026Download
    • Readings · source · confidence
    • signature.wet_signedyes
      from workers_comp_signed0.97
    • signature.date2026-06-02
      from workers_comp_signed0.97

Agent recommendation

request revision

Request revision

This application requires revision before it can move forward. Of 60 automated checks, 59 passed and 1 failed. The single failure involves the proposed side setback, which falls short of the minimum required under the applicable code path. The recommendation is request-revision.

pipeline-v1 · rules sacramento-adu-v1 · claude-sonnet-4-6 · started Jun 7, 2026, 2:26 AM · finished Jun 7, 2026, 2:26 AM

Determination

Your judgment, your signature

The recommendation is a draft (request-revision) — nothing is decided until you sign.

Prefilled from the agent narrative with citations — edit freely before signing.

Enter your reviewer name to sign — every determination is attributed.

Documentary

completeness — decided deterministically

Objective

measured against code values — decided deterministically
  • 2025 CRC R303–R306 (habitability minimums; research cites the 7-ft ceiling figure — exact subsection not pinned in research, see gap)
  • CDD-0200 p. 2 item 19; CDD-0312 cover-sheet item 6
  • CDD-0200 p. 2 item 24; CDD-0312 cover-sheet item 3
  • 17.228.105(A)
  • 17.228.105(C)(1)
  • 17.228.105(C)(1)(a)-(b)
  • 17.228.105(C)(1)(b)
  • 17.228.105(C)(1)(b)
  • 17.228.105(C)(1)(b)
  • 17.228.105(C)(1)(b)
  • 66323(a)(2), (b)
  • 66321(b)(3)
  • 66323(d)

Judgment

never auto-decided — flagged for your review

No judgment checks applied to this application.