Skip to content

Application review

1684 Fernwood Street, Sacramento, CA 95822

Determined

APN 008-0241-019 · app_fc8e4e36-d62a-404f-a74b-51cadf24056e · submitted May 22, 2026 · accepted complete May 22, 2026

Completeness determinationnot started
Decision53 of 60 days left

City cycle targets for residential new buildings: 20/15/5 working days for cycles 1/2/3 (CDD-0294, rev 03-04-2026) — an expectation, not a promise.

Parcel

APN
008-0241-019
Zone
R-1
Lot area
5,200 sq ft
Overlays
none
GIS source
demo-snapshot · fetched Jun 10, 2026

Application

Standards path
B — State standards (≤800 sf, 18 ft, 4-ft setbacks)
Permit holder
Property owner
Valuation
$123,000
New sq ft (living)
720 (720 first / 0 second)
Garage sq ft
0
Stories
1
Description of work
Construct a new detached single-story 720 sq ft accessory dwelling unit (1 bedroom / 1 bath) under the state ADU standards, all-electric with 2.0 kW rooftop solar PV.

Documents

  • 1684-fernwood-st-cyc1-cdd0104-address-request.pdfcdd0104 · v1 · uploaded May 22, 2026Download
  • 1684-fernwood-st-cyc1-cdd0200-rendered.pdfcdd0200_rendered · v1 · uploaded May 20, 2026Download
  • 1684-fernwood-st-cyc1-cdd0220-owner-builder-wet-signed.pdfcdd0220 · v1 · uploaded May 22, 2026Download
  • 1684-fernwood-st-cyc1-final-cert-wet-signed.pdffinal_certification_signed · v1 · uploaded May 22, 2026Download
  • 1684-fernwood-st-cyc1-owner-builder-declaration-wet-signed.pdfowner_builder_declaration_signed · v1 · uploaded May 22, 2026Download
  • 1684-fernwood-st-cyc1-plan-set.pdfplan_set · v1 · uploaded May 22, 2026Download
    • Readings · source · confidence
    • cover_sheet.address
      1684 Fernwood Street, Sacramento, CA 95822from plan_set0.97
    • cover_sheet.sheet_indexyes
      from plan_set0.97
    • cover_sheet.work_description
      Construct a new detached single-story 720 sq ft accessory dwelling unit (1 bedroom / 1 bath) under the state ADU standards, all-electric with 2.0 kW rooftop solar PV.from plan_set0.97
    • cover_sheet.description_of_work
      Construct a new detached single-story 720 sq ft accessory dwelling unit (1 bedroom / 1 bath) under the state ADU standards, all-electric with 2.0 kW rooftop solar PV.from plan_set0.97
    • cover_sheet.occupancyR-3
      from plan_set0.97
    • cover_sheet.construction_typeV-B
      from plan_set0.97
    • cover_sheet.sprinklersno
      from plan_set0.97
    • cover_sheet.sprinklers_primaryno
      from plan_set0.97
    • cover_sheet.toilet_counts
      Primary dwelling: 2 water closets; ADU: 1 water closetfrom plan_set0.97
    • cover_sheet.building_typeall_electric
      from plan_set0.97
    • cover_sheet.designer_declarationyes
      from plan_set0.97
    • cover_sheet.codes_declarationyes
      from plan_set0.97
    • cover_sheet.code_cycle_declaration
      2025 California Building Standards Code (Title 24) with City of Sacramento amendments per Ord. 2025-0031 / City Code §15.04.050, effective 1-1-2026from plan_set0.97
    • site_plan.utility_connection_pointsyes
      from plan_set0.97
    • site_plan.abandoned_septic_noteno abandoned septic on site
      from plan_set0.97
    • site_plan.setbacks_dimensionedyes
      from plan_set0.97
    • site_plan.north_arrowyes
      from plan_set0.97
    • site_plan.easements_driveways_drainageyes
      from plan_set0.97
    • site_plan.sewer_line_detailsyes
      from plan_set0.97
    • site_plan.side_setback_ft4.50
      from plan_set0.97
    • site_plan.rear_setback_ft5
      from plan_set0.97
    • site_plan.dist_to_front_line70
      from plan_set0.97
    • site_plan.separation_primary_ft10
      from plan_set0.97
    • site_plan.fire_separation_ft10
      from plan_set0.97
    • site_plan.adu_sqft720
      from plan_set0.97
    • site_plan.adu_footprint_sqft720
      from plan_set0.97
    • floor_plan.room_usesyes
      from plan_set0.97
    • floor_plan.dimensionsyes
      from plan_set0.97
    • floor_plan.window_door_sizes_typesyes
      from plan_set0.97
    • floor_plan.ceiling_height8'-0" typical
      from plan_set0.97
    • floor_plan.ceiling_height_ft8
      from plan_set0.97
    • elevations.views_nsewyes
      from plan_set0.97
    • elevations.height_ft15
      from plan_set0.97
    • sections.longitudinalyes
      from plan_set0.97
    • sections.transverseyes
      from plan_set0.97
    • structural_plans.foundation_footing_detailsyes
      from plan_set0.97
    • structural_plans.roof_ceiling_framingyes
      from plan_set0.97
    • structural_plans.floor_framingyes
      from plan_set0.97
    • structural_plans.braced_shear_wall_plansyes
      from plan_set0.97
    • structural_plans.connection_detailsyes
      from plan_set0.97
    • electrical_plan.panel_locations_amperage_busbaryes
      from plan_set0.97
    • electrical_plan.switch_receptacle_lighting_scaledyes
      from plan_set0.97
    • electrical_plan.meter_count2
      from plan_set0.97
    • title24_report.certificates_of_complianceyes
      from plan_set0.97
    • title24_report.code_cycle2025 CEnC
      from plan_set0.97
    • title24_report.climate_zone12
      from plan_set0.97
    • calgreen_checklist.cdd0183yes
      from plan_set0.97
    • pv_plans.module_layoutyes
      from plan_set0.97
    • pv_plans.one_line_diagramyes
      from plan_set0.97
    • pv_plans.spec_sheetsyes
      from plan_set0.97
    • pv_plans.cec_labelsyes
      from plan_set0.97
    • pv_plans.attachment_detailsyes
      from plan_set0.97
    • pv_plans.smud_confirmation_letteryes
      from plan_set0.97
    • site_plan.has_balconyno
      from plan_set0.97
    • site_plan.fencing_in_scopeno
      from plan_set0.97
    • site_plan.adu_in_front_setbackno
      from plan_set0.97
  • 1684-fernwood-st-cyc1-cdd0312-checklist.pdfsubmittal_checklist_copy · v1 · uploaded May 22, 2026Download
  • 1684-fernwood-st-cyc1-workers-comp-wet-signed.pdfworkers_comp_signed · v1 · uploaded May 22, 2026Download

Agent recommendation

approve

Approve

All 59 automated checks passed with no flags or failures. There are no outstanding issues identified by the rule engine, and the computed recommendation is to approve this permit application.

pipeline-v1 · rules sacramento-adu-v1 · claude-sonnet-4-6 · started May 22, 2026, 2:26 AM · finished May 22, 2026, 2:26 AM

Signed determination

Approve

Signed by Maria Chen, Senior Plan Check Engineer (demo) at May 29, 2026, 2:26 AM

All automated checks passed with citations. Approved for issuance subject to standard conditions. (Demo determination.)

Starts a fresh check run for resubmission review — prior runs and this determination are preserved.

Documentary

completeness — decided deterministically

Objective

measured against code values — decided deterministically
  • 2025 CRC R303–R306 (habitability minimums; research cites the 7-ft ceiling figure — exact subsection not pinned in research, see gap)
  • CDD-0200 p. 2 item 19; CDD-0312 cover-sheet item 6
  • CDD-0200 p. 2 item 24; CDD-0312 cover-sheet item 3
  • 17.228.105(A)
  • 17.228.105(C)(1)
  • 17.228.105(C)(1)(a)-(b)
  • 17.228.105(C)(1)(b)
  • 17.228.105(C)(1)(b)
  • 17.228.105(C)(1)(b)
  • 17.228.105(C)(1)(b)
  • 66323(a)(2), (b)
  • 66321(b)(3)
  • 66323(d)

Judgment

never auto-decided — flagged for your review

No judgment checks applied to this application.