Skip to content

Application review

1316 Weller Way, Sacramento, CA 95818

In review

APN 021-0143-027 · app_18125582-f810-4f1b-a441-fd5267b8460b · submitted May 3, 2026 · accepted complete May 3, 2026

Completeness determination14 of 15 days left
Decision20 of 60 days left

City cycle targets for residential new buildings: 20/15/5 working days for cycles 1/2/3 (CDD-0294, rev 03-04-2026) — an expectation, not a promise.

Parcel

APN
021-0143-027
Zone
R-1
Lot area
6,000 sq ft
Overlays
none
GIS source
demo-snapshot · fetched Jun 10, 2026

Application

Standards path
A — Local option (≤1,200 sf combined)
Permit holder
Property owner
Valuation
$112,000
New sq ft (living)
640 (640 first / 0 second)
Garage sq ft
0
Stories
1
Description of work
Construct a new detached 640 sf one-story accessory dwelling unit (studio / 1 bath) beside the existing single-family home; all-electric, rooftop PV.

Documents

  • tran-cdd0104-address-request.pdfcdd0104 · v1 · uploaded May 2, 2026Download
    • Readings · source · confidence
    • address_request.completeyes
      from cdd01040.97
  • tran-CYC1-APP-cdd0200.pdfcdd0200_rendered · v1 · uploaded May 2, 2026Download
    • Readings · source · confidence
    • package.app_size_mb9.60
      from cdd0200_rendered0.97
    • package.export_naming_compliantyes
      from cdd0200_rendered0.97
    • package.bookmarks_compliantyes
      from cdd0200_rendered0.97
    • document.pdf_restrictions_compliantyes
      from cdd0200_rendered0.97
  • tran-cdd0220-owner-builder-wet-signed.pdfcdd0220 · v1 · uploaded May 3, 2026Download
    • Readings · source · confidence
    • signature.wet_signedyes
      from cdd02200.97
    • acknowledgments.initialed_count12
      from cdd02200.97
  • tran-final-certification-wet-signed.pdffinal_certification_signed · v1 · uploaded May 2, 2026Download
    • Readings · source · confidence
    • signature.wet_signedyes
      from final_certification_signed0.97
    • signature.date2026-06-02
      from final_certification_signed0.97
  • tran-owner-builder-declaration-wet-signed.pdfowner_builder_declaration_signed · v1 · uploaded May 2, 2026Download
    • Readings · source · confidence
    • signature.wet_signedyes
      from owner_builder_declaration_signed0.97
    • signature.date2026-06-02
      from owner_builder_declaration_signed0.97
  • tran-adu-plan-set.pdfplan_set · v1 · uploaded May 2, 2026Download
    • Readings · source · confidence
    • cover_sheet.address
      1316 Weller Way, Sacramento, CA 95818from plan_set0.97
    • cover_sheet.sheet_indexyes
      from plan_set0.97
    • cover_sheet.work_description
      Construct a new detached 640 sf one-story accessory dwelling unit (studio / 1 bath) beside the existing single-family home; all-electric, rooftop PV.from plan_set0.97
    • cover_sheet.description_of_work
      Construct a new detached 640 sf one-story accessory dwelling unit (studio / 1 bath) beside the existing single-family home; all-electric, rooftop PV.from plan_set0.97
    • cover_sheet.occupancyR-3
      from plan_set0.97
    • cover_sheet.construction_typeV-B
      from plan_set0.97
    • cover_sheet.sprinklersno
      from plan_set0.97
    • cover_sheet.sprinklers_primaryno
      from plan_set0.97
    • cover_sheet.toilet_counts
      primary dwelling: 2 WC; ADU: 1 WCfrom plan_set0.97
    • cover_sheet.building_typeall_electric
      from plan_set0.97
    • cover_sheet.designer_declarationyes
      from plan_set0.97
    • cover_sheet.codes_declaration
      2025 Title 24 with City of Sacramento amendments (ORD 2025-0031; City Code §15.04.050)from plan_set0.97
    • cover_sheet.code_cycle_declaration
      2025 Title 24 with City of Sacramento amendments (ORD 2025-0031; City Code §15.04.050)from plan_set0.97
    • site_plan.utility_connection_pointsyes
      from plan_set0.97
    • site_plan.abandoned_septic_notenone on parcel
      from plan_set0.97
    • site_plan.setbacks_dimensionedyes
      from plan_set0.97
    • site_plan.north_arrowyes
      from plan_set0.97
    • site_plan.easements_driveways_drainageyes
      from plan_set0.97
    • site_plan.sewer_line_details
      4-in ABS, 2% slope, tie-in at existing lateralfrom plan_set0.97
    • site_plan.side_setback_ft5
      from plan_set0.97
    • site_plan.rear_setback_ft2.50
      from plan_set0.97
    • site_plan.front_setback_ft22
      from plan_set0.97
    • site_plan.dist_to_front_line42
      from plan_set0.97
    • site_plan.separation_primary_ft7.50
      from plan_set0.97
    • site_plan.adu_sqft640
      from plan_set0.97
    • site_plan.adu_footprint_sqft640
      from plan_set0.97
    • site_plan.fire_separation_ft10
      from plan_set0.97
    • site_plan.utility_equipment_screenedyes
      from plan_set0.97
    • floor_plan.room_usesyes
      from plan_set0.97
    • floor_plan.dimensionsyes
      from plan_set0.97
    • floor_plan.window_door_sizes_typesyes
      from plan_set0.97
    • floor_plan.ceiling_heightyes
      from plan_set0.97
    • floor_plan.ceiling_height_ft8
      from plan_set0.97
    • floor_plan.entrance_faces_roadway_or_open_spaceyes
      from plan_set0.97
    • elevations.views_nsewyes
      from plan_set0.97
    • elevations.height_ft14
      from plan_set0.97
    • elevations.blank_wall_area_sqft120
      from plan_set0.97
    • elevations.mechanical_equipment_concealedyes
      from plan_set0.97
    • sections.longitudinalyes
      from plan_set0.97
    • sections.transverseyes
      from plan_set0.97
    • structural_plans.foundation_footing_detailsyes
      from plan_set0.97
    • structural_plans.roof_ceiling_framingyes
      from plan_set0.97
    • structural_plans.floor_framingyes
      from plan_set0.97
    • structural_plans.braced_shear_wall_plansyes
      from plan_set0.97
    • structural_plans.connection_detailsyes
      from plan_set0.97
    • electrical_plan.panel_locations_amperage_busbaryes
      from plan_set0.97
    • electrical_plan.switch_receptacle_lighting_scaledyes
      from plan_set0.97
    • electrical_plan.meter_count1
      from plan_set0.97
    • title24_report.certificates_of_complianceyes
      from plan_set0.97
    • title24_report.code_cycle2025
      from plan_set0.97
    • title24_report.climate_zone12
      from plan_set0.97
    • calgreen_checklist.cdd0183yes
      from plan_set0.97
    • pv_plans.module_layoutyes
      from plan_set0.97
    • pv_plans.one_line_diagramyes
      from plan_set0.97
    • pv_plans.spec_sheetsyes
      from plan_set0.97
    • pv_plans.cec_labelsyes
      from plan_set0.97
    • pv_plans.attachment_detailsyes
      from plan_set0.97
    • pv_plans.smud_confirmation_letteryes
      from plan_set0.97
    • plan_set.vector_contentyes
      from plan_set0.97
    • plan_set.sheet_size_scale_compliantyes
      from plan_set0.97
    • package.plans_size_mb42.70
      from plan_set0.97
    • site_plan.lot_coverage_pct29.80
      from plan_set0.97
    • site_plan.has_balconyno
      from plan_set0.97
    • site_plan.fencing_in_scopeno
      from plan_set0.97
    • site_plan.adu_in_front_setbackno
      from plan_set0.97
  • tran-cdd0312-checklist.pdfsubmittal_checklist_copy · v1 · uploaded May 2, 2026Download
    • Readings · source · confidence
    • checklist.formCDD-0312 rev 01-21-2025
      from submittal_checklist_copy0.97
  • tran-workers-comp-wet-signed.pdfworkers_comp_signed · v1 · uploaded May 2, 2026Download
    • Readings · source · confidence
    • signature.wet_signedyes
      from workers_comp_signed0.97
    • signature.date2026-06-02
      from workers_comp_signed0.97

Agent recommendation

request revision

Request revision

This application is recommended for revision. Of 65 checks run, 64 passed and 1 failed. The single failure involves a rear setback that falls short of the minimum required distance for an ADU located within 60 feet of the front property line. The applicant will need to revise the plans to bring the rear setback into compliance before the application can move forward.

pipeline-v1 · rules sacramento-adu-v1 · claude-sonnet-4-6 · started May 3, 2026, 2:26 AM · finished May 3, 2026, 2:26 AM

Determination

Your judgment, your signature

The recommendation is a draft (request-revision) — nothing is decided until you sign.

Prefilled from the agent narrative with citations — edit freely before signing.

Enter your reviewer name to sign — every determination is attributed.

Documentary

completeness — decided deterministically

Objective

measured against code values — decided deterministically

Judgment

never auto-decided — flagged for your review

No judgment checks applied to this application.